IEEE/ICACT20210161 Question.3
Questioner: lijingwei10@huawei.com    2021-02-09 ¿ÀÀü 12:45:42
IEEE/ICACT20210161 Answer.3
Answer by Auhor angie_teo236@hotmail.com   2021-02-09 ¿ÀÀü 12:45:42
Have other researchers done the similar simulation before? And what is the feature of your simulation? Other researchers performed simulation focusing on single polarization mode. The novelty of this paper is that simulation is performed on both single mode and higher order mode. This is because we do not want undesirable higher-order modes which result in more noise and losses. If only single order is simulated, then we might not know if higher order will come in at that specific dimension. In addition to that, the study of the performance of each mode is required as different device will need different performances, that is why we need to find it out by carrying out simulation on not only single but higher order mode.