IEEE/ICACT20230270 Slide.08        [Big Slide]       Oral Presentation
The membership functions (MFs) of the 2 inputs FIS were presented in Fig. 2. In (a), there were 3 states that were cold, good, and hot. They were defined by the error of the setpoint temperature between -20 and +20 degree C. The shapes of the MFs were all triangles. In (b), there were also 3 states that were low, middle, and high. They were defined by the error of the setpoint flow between -1 and +1. The shapes of the MFs were all triangles, too. All of the MFs are integrated in (c) [13-15].